
『thermal flow|magnetic flow meter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Workbench Thermal Conductivity and Stress Calculation
Workbench provides two thermal conductivity analysis modules: Steady State Thermal and Transient Thermal, which are used to solve the thermal conductivity problem of solids and obtain the temperature distribution of solids. For the calculation of the temperature field of fluids, the Fluent module is used. The following will provide a detailed introduction to the analysis methods of solid thermal conduction (including steady-state and transient thermal conduction), the explanation of boundary conditions, and the calculation process of thermal stress.
1. Basic Steps of Thermal Conductivity Analysis The basic steps of thermal conductivity analysis are similar to those of structural analysis, mainly including the following processes: defining material parameters for steady-state thermal conductivity: it is necessary to define the thermal conductivity.
. Transient heat conduction: In addition to thermal conductivity, specific heat (unit: J/kg/° C) and density (unit: kg/m ³) also need to be defined. Thermal stress calculation: It is also necessary to define the thermal expansion coefficient (unit: 1/° C), elastic modulus (unit: Pa), and Poissons ratio of the material. Geometric models can be created in 3D modeling software and imported into ANSYS, or created using DM or SCDM. Note: If using SurfaceBody, ignore the temperature gradient in the thickness direction; For Line Body, ignore the temperature gradient on the cross-section. Preprocessing includes meshing and setting contact parameters. The basic rules of grid division are similar to structural simulation, where the grid should be appropriately densified at locations with large temperature gradi
2. Steady state heat conduction analysis In steady-state heat conduction analysis, the temperature distribution does not change over time.
. The following is a detailed process for steady-state heat conduction analysis: Define material parameters and define thermal conductivity in Engineering Data. Create geometric models using 3D modeling software or DM/SDM in Workbench. Grid division is based on the geometric model and temperature gradient distribution. Apply boundary conditions to add thermal loads such as heat flux, heat flux, or heat generation. Set boundary conditions such as constant temperature boundary, convective boundary, or radiation boundary. Analyze option settings to set load steps, non-linear settings, and output settings. After processing the results, check the temperature distribution and heat flux.III.

Current position > News detail