1. Welding Machine Translation 4
C: Installation: C: Installation Distribution Box Power Distribution Box Argon Gas Meter Gas Cylinder Gas Cylinders Argon Welding Torch Welding Clamp Electrode Holder Grounding
1. The machine is placed in a well ventilated position, and the fan is not covered or blocked to prevent the cooling system from failing due to poor ventilation. There should be good ventilation at the location of machine, make sure that the ventilation fan is not covered and blocked, precaution should be taken to prevent failure of the cooling system due to lack of ventilation.
2、 Connect the protective gas and the gas supply circuit should include gas cylinders, argon gas, pressure reducing flow meters, and gas pipes; The connection part of the trachea should be tightly fastened with a throat clamp or other object to prevent argon gas leakage and air from entering. Protected gas should be connected properly; gas supply cycle should include gas cylinder, argon gas, decompression flowmeter and gas tube; to prevent the leakage of argon gas and the inflow of air, gas tube joint should be secured tightly by using hose clamp or other methods,
3、 Use a wire with a conductive cross-sectional area of not less than 6mm ² to reliably ground the chassis. The method is to connect the grounding screw on the back of the welding machine to the grounding device. For effective grounding, connect one end of a conductor wire with a cross-sectional area of not less than 6 mm² to the grounding screw at the back of the welding machine, and connect the other end to the grounding device.
4、 Insert the quick plug of the circuit cable into the quick socket with a polarity of "+" on the welding machine panel, and tighten it clockwise with force, while the ground clamp on the other end clamps the workpiece. Connect the fast plug of the loop cable to the fast outlet marked “+”on the panel of welding machine, tighten strongly by screwing clockwise; Clip the other end of the grounding clamp on the well object.
2. The intelligent target flowmeter displays zero
Xuner Instrument answers for you:
1. There is no flow passing through the pipeline;
; Solution: Please confirm if the valve is open, if the bypass is closed, and if there is already flow passing through the flow transmitter.2、 Damaged header; Solution: Unscrew the meter head and, under the premise of power on operation, use a magnetic head screwdriver to quickly slide on the bottom end face to observe if there is a flow display. If there is, it is normal; If not, it can be determined that the header of this converter is damaged. Please contact the manufacturer.
3、 The impeller is stuck and cannot work; Solution: Remove the stainless steel body from the pipeline, observe and turn (blow) the impeller. If you find that the wire or hard object is stuck on the impeller, please clean and tidy it up immediately so that it can rotate freely. If the impeller or shaft is found to be damaged, please contact the manufacturer.
4、 The traffic is too small; Solution: Please confirm if the current flow rate is below the lower measurement limit, as it may cause abnormal display. Increase traffic and observe if normal operation can be restored. 5. Internal parameters have been modified; Solution: Check if the coefficient of the flowmeter instrument from 6-1 to 6-6 is zero. If so, please contact our factory. For detailed information, ple